    Technical Specification:
    ① Electrical indicators

    a. The nominal power of mineral insulated heating cable is 10W/m~150W/m;

    b. Rated voltage: 220VAC;

    c. The use length is 5~50m (the maximum heating length is different for different powers);

    d. Equipped with a circuit breaker with a current value of 6A to 32A, and a power distribution switch with a leakage protector;

    e. Must be equipped with a temperature control instrument.

② Thermal index

a. At an ambient temperature of -20°C and a wind speed of 15m/s, the temperature inside the tube is maintained at 200°C ~ 400°C;

b. The sampling tube can withstand corrosion from various acid and alkali media, with a compressive strength of 1.0Mpa and no leakage;

c. The sampling tube can work for a long time at temperatures <400°C;

③ Installation indicators

a. The minimum radius of curvature of the composite pipe is 0.6m;

b. Maximum continuous length 50m;

c. Minimum installation temperature -20℃;

d. Minimum fixed distance: 5m in vertical direction, 2m in horizontal direction;

e. It is strictly prohibited to twist or drag on the ground during construction. The pipe head sheath is only allowed to be disassembled when installing the joint;

f. The sampling composite pipe should be laid away from the power cables.

Note: Twisting and dragging on the ground are strictly prohibited during construction.
The pipe head sheath is only allowed to be disassembled when installing the joint.

Technical Specification:

No.Schematic Cross-sectionModel&Specs No.Model&Specs
1FHG42-6-c-180-H(30)-P
①out diameter 42mm
②pipe 1pcs out diameter 6mm material: PFA
③Parallel constant wattage heat cable 1pcs HBL2-J3-30 30w/m
④reinforced jacket PVC
FHG42-8(2)-c-120-Z(50)-P
①out diameter 42mm
②pipe 2pcs out dia: 8mm; material:PFA
③self-regulating cable 1pcs 50ZWK2-P 50w/m
④reinforced jacket PVC
2FHG42-6(5)-c-80-Z(35)-P
①out dia: 42mm
②pipe 5pc sout dia: 6mm material: PFA
③self-regulating heat cable 1pcs 35ZWK2-P 25w/m
④reinforced jacket PVC
FHG45-8(3)-6(2) 80-Z(50)-Z(50)-P-D
①out dia: 45mm
②pipe 5pcs material FEP, 3pcs out dia: 8mm; 2pcs out dia: 6mm
③1pcs self-regulating cable 50ZWK2-P 50w/m
④One compensation cable
⑤One instrument cable
⑥reinforced jacket PVC
3FHG42-8-8-b-c-80-Z(50)-P
①out dia: 42mm
②1pcs sample out dia: 8mm
material: PFA
out dia: 8mm
material: FEP
③1pcs self-regulating cable 50ZWK2-P 50w/m
④reinforced PVC
FHG42-6-b-80-Z(25)-P
①out dia: 42mm
②sampling pipe out dia: 6mm; material: FEP
③MI cable 1pcs MISS-2 25W/m
④reinforced PVC