a. The nominal power of parallel wattage heating cable is 30W/m, 40W/m, 50W/m;
b. Rated voltage: 220VAC;
c. Using length ≤150m;
d. Equipped with circuit breaker current value 6A ~ 32A, distribution switch with leakage protector;
e. Must be equipped with temperature control instruments.
a. At an ambient temperature of -20°C and a wind speed of 15m/s, the temperature inside the pipe is maintained at 40-180°C;
b. The sampling pipe can withstand corrosion from various acid and alkali media, and has a pressure resistance of 1.0Mpa without leakage;
c. The sampling tube can work at temperatures <100°C for a long time.
a. The minimum radius of curvature of composite pipe is 0.5m;
b. The maximum continuous use length is 100~150m;
c. Minimum installation temperature -20℃;
d. Minimum fixed distance: 5m in vertical direction, 2m in horizontal direction;
e. It is strictly prohibited to twist or drag on the ground during construction, and the pipe head sheath is only allowed to be removed when installing the joint;
f. The sampling composite pipe should be laid away from the power cables.
Note: Twisting and dragging on the ground are strictly prohibited during construction.
The pipe head sheath is only allowed to be disassembled when installing the joint.